• 云顶集团3118(中国)

    PCR cleanup and size selection with magnetic beads

    Dominik Buchner

    Published: 2022-10-11 DOI: 10.17504/protocols.io.36wgqj45xvk5/v2
    AI 解读
    浏览 1565

    Abstract

    This protocol describes how to clean up PCR products or DNA extracts and perform a size selection with carboxylated-magnetic beads and a PEG-NaCl buffer. It can also be used for volume reduction of a sample or for buffer exchange.

    Before start

    Make sure all buffers are prepared before starting.

    For easier pipetting let the bead-solution adjust to Room temperature

    Note
    The protocol described here is designed for the use of 250µL but can also be done in tubes, PCR plates, strips, or any sufficient reaction vessel. The recommended shaking speeds are adjusted to the plates mentioned in the materials.

    Steps

    1.

    Shake the cleanup solution until the beads are homogeneously resuspended

    Note
    The protocol described here uses a cleanup solution to sample ratio of 0.8:1. This is sufficient for the removal of primer and primer dimers below a size of 200 bp. For the removal of shorter or larger fragments, the ratio has to be adjusted accordingly. For more information on ratios refer to the material provided in the tab "Guidelines".

    2.

    Add 30µL and 32µL to a 250µL U-bottom assay plate

    Note
    It's recommended to increase the volume of the sample with PCR-grade water for easier liquid handling but also to lower relative pipetting error (e.g. if the pipette is off by 2µL the effect on the ratio is larger if working with a 10µL assay than when working with a 80µL assay.The amount of beads is calculated as follows:(sample volume + water volume) * ratio = cleanup solution volumeIn this example:(10µL +30µL ) * 0.8 = 32µL For higher sample numbers PCR-grade water and cleanup solution can be prepared as a master mix.

    3.

    Add 10µL of sample.

    Note
    This protocol works for the cleanup of PCR products as well as the cleanup of DNA extracts or for buffer exchange after enzyme treatment of samples.

    4.

    To bind the DNA to the beads shake at 900rpm

    Note
    If the protocol is not done in plates mixing can also be accomplished by pipetting or vortexing.

    5.

    Place the plate on a magnet to pellet the beads for 0h 2m 0s

    Note
    Depending on the magnet and volume used separation times may vary and have to be adjusted accordingly.

    6.

    Discard the supernatant by pipetting

    7.

    With the plate still on the magnet, add 100µL to each sample

    8.

    Incubate for at least 0h 0m 30s

    9.

    Discard the supernatant by pipetting

    10.
    11.

    With the plate still on the magnet, incubate the plate for 0h 5m 0s at50Room temperature to dry off residuals of wash buffer

    12.

    Add 40µL to each sample

    13.

    900rpm

    14.

    Place the plate on a magnet to pellet the beads for 0h 2m 0s

    15.

    Transfer 30µL of the DNA to a new PCR plate. Store at -20°C

    Note
    Leaving 10µL of elution buffer is recommended to avoid carry-over of beads. If all of the DNA is needed for subsequent analysis try to pipette slowly without disturbing the pellet.